PERIODIC REPLACEMENT OF DEFINED LIFE PARTS
For using the machine safely for an extended period of time, you must periodically replace the safety critical and
fire prevention-related parts listed in the table of the defined life parts.
Material quality of these parts can change as time passes and they are likely to wear out or deteriorate. Howev-
er, it is difficult to determine the extent of wear or deterioration at the time of periodic maintenance. Hence, it is
required to replace them with new ones regardless of their condition after a certain period of usage. This is im-
portant to ensure that these parts maintain their full performance at all times.
Furthermore, should anything abnormal be found on any of these parts, replace it with a new one even if the
periodic replacement time for the part has not yet arrived.
If any of the hose clamps show deterioration like deformation or cracking, replace the clamps at the same time
as the hoses.
Also perform the following checks with hydraulic hoses which need not to be replaced periodically. Tighten all
loose hoses and replace defective hoses, as required.
When replacing hoses, always replace O-rings, gaskets, and other such parts at the same time.
Have your Komatsu distributor replace the defined life parts.
PERIODIC REPLACEMENT OF DEFINED LIFE PARTS
REPLACEMENT PARTS
7-2
Summary of Contents for PC1250-11
Page 2: ......
Page 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Page 24: ......
Page 66: ......
Page 377: ...Boom d Left side e Right side f Head side g Foot side MAINTENANCE MAINTENANCE PROCEDURE 4 61...
Page 378: ...Arm h Left side i Right side MAINTENANCE PROCEDURE MAINTENANCE 4 62...
Page 400: ......
Page 401: ...SPECIFICATIONS 5 1...
Page 406: ......
Page 435: ...REPLACEMENT PARTS 7 1...
Page 444: ......