1.
Turn the top of the engine emergency shut down switch
(S) clockwise.
The switch protrudes a little and it returns to OFF (normal
operation) position (b). At this time, check that the indicator
lamp (L) in cab is not lit.
2.
Turn the starting switch key to ON position (B).
3.
Start the engine.
REMARK
If the engine is stopped by the operation of engine emergency shut down switch, air bleeding from fuel circuit is
not necessary.
METHOD FOR STOPPING ENGINE FROM GROUND IN EMERGENCY
(if equipped)
NOTICE
This engine emergency shut down switch is used to disable the starting of engine from inside of cab
when performing the inspection and maintenance of the machine bottom or tracks.
In normal cases, keep the engine emergency shut down switch to OFF (normal operation) position.
MACHINE OPERATIONS AND CONTROLS
OPERATION
3-170
Summary of Contents for PC1250-11
Page 2: ......
Page 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Page 24: ......
Page 66: ......
Page 377: ...Boom d Left side e Right side f Head side g Foot side MAINTENANCE MAINTENANCE PROCEDURE 4 61...
Page 378: ...Arm h Left side i Right side MAINTENANCE PROCEDURE MAINTENANCE 4 62...
Page 400: ......
Page 401: ...SPECIFICATIONS 5 1...
Page 406: ......
Page 435: ...REPLACEMENT PARTS 7 1...
Page 444: ......