EVERY 4500 HOURS MAINTENANCE
Maintenance for every 10, 100, 250 and 500 hours should be performed at the same time.
METHOD FOR CLEANING KDPF
Contact your Komatsu distributor for cleaning of the KDPF.
METHOD FOR CLEANING FUEL DOSER
For cleaning the fuel doser, ask your Komatsu distributor.
CHECK FOR MISSING FUEL SPRAY PREVENTION CAP ON FUEL DOSER PIP-
ING, HARDENING OF RUBBER
Check the fuel spray prevention caps (1) and (2) visually or with a finger to see if any of them has slipped off, or
if the rubber portion is hardened.
If there is any problem, the related parts must be replaced. Ask your Komatsu distributor for replacement.
EVERY 5000 HOURS MAINTENANCE
Maintenance for every 10, 100, 250, 500 and 1000 hours should be performed at the same time.
METHOD FOR CHANGING OIL IN HYDRAULIC TANK, CLEANING HYDRAULIC
TANK STRAINER
k
k
WARNING
• Immediately after the engine is stopped, its parts and oil are still very hot and may cause burn in-
jury. Wait for the temperature to go down, and then start the work.
• When removing the oil filler cap, the oil may spurt out. Turn it slowly to release the internal pres-
sure, then remove it carefully.
Refill capacity: 670 ℓ
Items to be prepared
• Container to catch the drained oil
• Socket wrench handle
MAINTENANCE
MAINTENANCE PROCEDURE
4-79
Summary of Contents for PC1250-11
Page 2: ......
Page 11: ...Do not repeatedly handle and lift loads FOREWORD VIBRATION LEVELS 1 9...
Page 24: ......
Page 66: ......
Page 377: ...Boom d Left side e Right side f Head side g Foot side MAINTENANCE MAINTENANCE PROCEDURE 4 61...
Page 378: ...Arm h Left side i Right side MAINTENANCE PROCEDURE MAINTENANCE 4 62...
Page 400: ......
Page 401: ...SPECIFICATIONS 5 1...
Page 406: ......
Page 435: ...REPLACEMENT PARTS 7 1...
Page 444: ......