TOS9213S/ TOS9213AS
7-35
Returning in insulation resistance testing
Test type (2: IR), monitor voltage, monitor resistance NORM, monitor resistance
MIN, monitor current, 0, elapsed (remaining) time, test status (0: Rise/1: Test/3: End)
(Example) If an DC withstanding voltage test is under way at a monitor voltage of
2.50 k
V
, monitor current NORM of 5.2 mA, monitor current MAX of 12
mA, monitor resistance MIN of 10 M
Ω
, and remaining time of 2.6 s,
“
1,2.5E3,5.2E-3,12E-3,10E6,0,2.6,1
” is returned.
• In insulation resistance testing with the lower judgment function off, even if set-
) is detected during the test, the measurement
voltage value flashes on the LCD. In this case, -1 is returned. In this case, -1 is
returned.
• In insulation resistance testing, when the resistance value to exceed 9.99 G
Ω
is detected.
9.99 G
Ω
< 99.9 G
Ω
:The returned resistance value is not warranted.
99.9 G
Ω
≤
: “99.9” flashes on the LCD and -1 is returned.
SCANTYPE (STYP)
Inquires about the number of valid connected channels and the model name of the
scanner.
Message
Query:
SCANTYPE?
STYP?
Response
To STYP
?
, the number of valid channels and the model name of the scanner are
returned as follows:
Number of valid channels, scanner 1, scanner 2, scanner 3, scanner 4
0: None; 1: TOS9220; 2: TOS9221
(Example) If there are 12 valid channels and scanners TOS9220, TOS9220, and
TOS9221 (in that order, from the nearest to the tester) are connected
without a fourth scanner connected,
“
12,1,1,2,0
” is returned.
CFAILCH (CFCH)
Inquires about the channel in the C FAIL status.
Message
Query:
CFAILCH?
CFCH?
Response
To CFCH
?
, the channel in the CONTACT FAIL status is returned.
(Example) If channel 12 is currently in the CONTACT FAIL status,
12
is returned.
NOTE