Keysight P9241/42/43A Oscilloscopes SCPI Programmer's Guide
5
Commands Quick Reference
:FUNCtion<m>[:FFT]:VT
YPe <units> (see
:FUNCtion<m>[:FFT]:VT
<units> ::= {DECibel | VRMS} for
the FFT (magnitude) operation
<units> ::= {DEGRees | RADians}
for the FFTPhase operation
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>[:FFT]:WI
NDow <window> (see
:FUNCtion<m>[:FFT]:WI
<window> ::= {RECTangular |
HANNing | FLATtop | BHARris |
BARTlett}
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>:FREQuenc
y:HIGHpass <3dB_freq>
(see
:FUNCtion<m>:FREQuenc
y:HIGHpass? (see
<3dB_freq> ::= 3dB cutoff
frequency value in NR3 format
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>:FREQuenc
y:LOWPass <3dB_freq>
(see
:FUNCtion<m>:FREQuenc
y:LOWPass? (see
<3dB_freq> ::= 3dB cutoff
frequency value in NR3 format
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>:INTegrat
e:IOFFset
<input_offset> (see
:FUNCtion<m>:INTegrat
e:IOFFset? (see
<input_offset> ::= DC offset
correction in NR3 format.
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>:LINear:G
AIN <value> (see
:FUNCtion<m>:LINear:G
<value> ::= 'A' in Ax + B, value
in NR3 format
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>:LINear:O
FFSet <value> (see
:FUNCtion<m>:LINear:O
<value> ::= 'B' in Ax + B, value
in NR3 format
<m> ::= 1 to (# math functions)
in NR1 format
:FUNCtion<m>:OFFSet
<offset> (see
:FUNCtion<m>:OFFSet?
<offset> ::= the value at center
screen in NR3 format.
The range of legal values is
+/-10 times the current
sensitivity of the selected
function.
<m> ::= 1 to (# math functions)
in NR1 format
Table 13
:FUNCtion<m> Commands Summary (continued)
Command
Query
Options and Query Returns
Summary of Contents for P9241
Page 1: ...Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 6: ...6 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 36: ...36 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 1 What s New...
Page 41: ...Setting Up 2 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 41...
Page 44: ...44 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 2 Setting Up...
Page 222: ...222 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 7 Root Commands...
Page 244: ...244 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands...
Page 256: ...256 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands...
Page 278: ...278 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 10 CHANnel n Commands...
Page 328: ...328 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands...
Page 386: ...386 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands...
Page 390: ...390 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands...
Page 416: ...416 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands...
Page 498: ...498 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 21 MEASure Commands...
Page 532: ...532 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 22 MTESt Commands...
Page 572: ...572 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 24 SAVE Commands...
Page 900: ...900 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 28 TIMebase Commands...
Page 1080: ...1080 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 31 WGEN w Commands...
Page 1142: ...1142 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 34 Error Messages...
Page 1344: ...1344 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide Index...