![Keysight P9241 Scpi Programmer'S Manual Download Page 1319](http://html1.mh-extra.com/html/keysight/p9241/p9241_scpi-programmers-manual_19616821319.webp)
Programming Examples
38
Keysight P9241/42/43A Oscilloscopes SCPI Programmer's Guide
1319
6
Add a reference to the SCPI.NET 3.0 driver:
a
Right-click the project you wish to modify (not the solution) in the Solution
Explorer window of the Microsoft Visual Studio environment.
b
Choose
Add Reference...
.
c
In the Add Reference dialog, select the
Browse
tab, and navigate to the
ScpiNetDrivers folder.
•
Windows XP: C:\Documents and Settings\All Users\Keysight\Command
Expert\ScpiNetDrivers
•
Windows 7: C:\ProgramData\Keysight\Command Expert\ScpiNetDrivers
d
Select the .dll file for your oscilloscope, for example
AgInfiniiVision3000X_02_00.dll
; then, click
OK
.
e
Right-click the project you wish to modify (not the solution) in the Solution
Explorer window of the Microsoft Visual Studio environment and choose
Properties
; then, select "InfiniiVision.ScpiNetInstrumentApp" as the
Startup
object
.
7
Build and run the program.
For more information, see the SCPI.NET driver help that comes with Keysight
Command Expert.
'
' Keysight SCPI.NET Example in Visual Basic .NET
' -------------------------------------------------------------------
' This program illustrates a few commonly used programming
' features of your Keysight oscilloscope.
' -------------------------------------------------------------------
Imports System
Imports System.IO
Imports System.Text
Imports Keysight.CommandExpert.ScpiNet.AgInfiniiVision3000X_02_00
Namespace InfiniiVision
Class ScpiNetInstrumentApp
Private Shared myScope As AgInfiniiVision3000X
Public Shared Sub Main(ByVal args As String())
Try
Dim strScopeAddress As String
strScopeAddress = _
"TCPIP0::10.112.94.136::hislip9-0.0::INSTR"
Console.WriteLine("Connecting to oscilloscope...")
Console.WriteLine()
myScope = New AgInfiniiVision3000X(strScopeAddress)
myScope.Transport.DefaultTimeout.[Set](10000)
' Initialize - start from a known state.
Initialize()
' Capture data.
Summary of Contents for P9241
Page 1: ...Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 6: ...6 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 36: ...36 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 1 What s New...
Page 41: ...Setting Up 2 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 41...
Page 44: ...44 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 2 Setting Up...
Page 222: ...222 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 7 Root Commands...
Page 244: ...244 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands...
Page 256: ...256 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands...
Page 278: ...278 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 10 CHANnel n Commands...
Page 328: ...328 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands...
Page 386: ...386 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands...
Page 390: ...390 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands...
Page 416: ...416 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands...
Page 498: ...498 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 21 MEASure Commands...
Page 532: ...532 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 22 MTESt Commands...
Page 572: ...572 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 24 SAVE Commands...
Page 900: ...900 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 28 TIMebase Commands...
Page 1080: ...1080 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 31 WGEN w Commands...
Page 1142: ...1142 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 34 Error Messages...
Page 1344: ...1344 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide Index...