598
Keysight P9241/42/43A Oscilloscopes SCPI Programmer's Guide
25
:SBUS<n> Commands
:SBUS<n>:CAN:SOURce
<source> (see
:SBUS<n>:CAN:SOURce?
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels)
in NR1 format
:SBUS<n>:CAN:TRIGger
<condition> (see
:SBUS<n>:CAN:TRIGger?
<condition> ::= {SOF | EOF |
IDData | DATA | FDData | IDRemote
| IDEither | ERRor | ACKerror |
FORMerror | STUFferror | CRCerror
| SPECerror | ALLerrors | BRSBit
| CRCDbit | EBActive | EBPassive
| OVERload | MESSage | MSIGnal |
FDMSignal}
:SBUS<n>:CAN:TRIGger:
IDFilter {{0 | OFF} |
{1 | ON}} (see
:SBUS<n>:CAN:TRIGger:
IDFilter? (see
{0 | 1}
:SBUS<n>:CAN:TRIGger:
PATTern:DATA <string>
(see
:SBUS<n>:CAN:TRIGger:
PATTern:DATA? (see
<string> ::= "nn...n" where n ::=
{0 | 1 | X | $}
<string ::= "0xnn...n" where n
::= {0,..,9 | A,..,F | X | $}
:SBUS<n>:CAN:TRIGger:
PATTern:DATA:DLC
<dlc> (see
:SBUS<n>:CAN:TRIGger:
PATTern:DATA:DLC?
<dlc> ::= integer between -1
(don't care) and 64, in NR1
format.
:SBUS<n>:CAN:TRIGger:
PATTern:DATA:LENGth
<length> (see
:SBUS<n>:CAN:TRIGger:
PATTern:DATA:LENGth?
<length> ::= integer from 1 to 8
in NR1 format
:SBUS<n>:CAN:TRIGger:
PATTern:DATA:STARt
<start> (see
:SBUS<n>:CAN:TRIGger:
PATTern:DATA:STARt?
<start> ::= integer between 0 and
63, in NR1 format.
:SBUS<n>:CAN:TRIGger:
PATTern:ID <string>
(see
:SBUS<n>:CAN:TRIGger:
PATTern:ID? (see
<string> ::= "nn...n" where n ::=
{0 | 1 | X | $}
<string ::= "0xnn...n" where n
::= {0,..,9 | A,..,F | X | $}
:SBUS<n>:CAN:TRIGger:
PATTern:ID:MODE
<value> (see
:SBUS<n>:CAN:TRIGger:
PATTern:ID:MODE? (see
<value> ::= {STANdard | EXTended}
:SBUS<n>:CAN:TRIGger:
SYMBolic:MESSage
<name> (see
:SBUS<n>:CAN:TRIGger:
SYMBolic:MESSage?
<name> ::= quoted ASCII string
Table 99
:SBUS<n>:CAN Commands Summary (continued)
Command
Query
Options and Query Returns
Summary of Contents for P9241
Page 1: ...Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 6: ...6 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 36: ...36 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 1 What s New...
Page 41: ...Setting Up 2 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 41...
Page 44: ...44 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 2 Setting Up...
Page 222: ...222 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 7 Root Commands...
Page 244: ...244 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands...
Page 256: ...256 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands...
Page 278: ...278 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 10 CHANnel n Commands...
Page 328: ...328 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands...
Page 386: ...386 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands...
Page 390: ...390 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands...
Page 416: ...416 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands...
Page 498: ...498 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 21 MEASure Commands...
Page 532: ...532 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 22 MTESt Commands...
Page 572: ...572 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 24 SAVE Commands...
Page 900: ...900 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 28 TIMebase Commands...
Page 1080: ...1080 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 31 WGEN w Commands...
Page 1142: ...1142 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 34 Error Messages...
Page 1344: ...1344 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide Index...