![Keysight P9241 Scpi Programmer'S Manual Download Page 357](http://html1.mh-extra.com/html/keysight/p9241/p9241_scpi-programmers-manual_1961682357.webp)
:FUNCtion<m> Commands
17
Keysight P9241/42/43A Oscilloscopes SCPI Programmer's Guide
357
:FUNCtion<m>[:FFT]:DETection:TYPE
Command Syntax
:FUNCtion<m>[:FFT]:DETection:TYPE <type>
<type> ::= {OFF | SAMPle | PPOSitive | PNEGative | NORMal | AVERage}
<m> ::= 1-4 in NR1 format
The :FUNCtion<m>[:FFT]:DETection:TYPE command sets the FFT detector
decimation type.
Detectors give you a way of manipulating the acquired data to emphasize different
features of the data. Detectors reduce (decimate) the number of FFT points to at
most the number of specified detector points. In this reduction, sampled FFT
points are bucketized, that is, split into a number of groups that equals the
specified number of detector points. Then, the points in each bucket are reduced
to a single point according to the selected detection type. The detector types are:
• OFF — No detector is used.
• SAMPle — Takes the point nearest to the center of every bucket.
• PPOSitive (+ Peak) — Takes the most positive point in every bucket.
• PNEGative (- Peak) — Takes the most negative point in every bucket.
• AVERage — Takes the average of all points in every bucket.
• NORMal — Implements a rosenfell algorithm. This method to picks either the
minimum or maximum sample in every bucket depending on whether the data
is monotonically increasing, decreasing, or varying. For details, see the
Spectrum Analysis Basics application note
at www.keysight.com.
When detectors are used, the FFT's output is decimated, and any analysis is
performed on the reduced or detected data set.
Query Syntax
:FUNCtion<m>[:FFT]:DETection:TYPE?
The :FUNCtion<m>[:FFT]:DETection:TYPE? query returns the FFT detector type
setting
Return Format
<type><NL>
<type> ::= {OFF | SAMPle | PPOSitive | PNEGative | NORMal | AVERage}
See Also
•
Summary of Contents for P9241
Page 1: ...Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 6: ...6 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 36: ...36 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 1 What s New...
Page 41: ...Setting Up 2 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 41...
Page 44: ...44 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 2 Setting Up...
Page 222: ...222 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 7 Root Commands...
Page 244: ...244 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands...
Page 256: ...256 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands...
Page 278: ...278 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 10 CHANnel n Commands...
Page 328: ...328 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands...
Page 386: ...386 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands...
Page 390: ...390 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands...
Page 416: ...416 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands...
Page 498: ...498 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 21 MEASure Commands...
Page 532: ...532 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 22 MTESt Commands...
Page 572: ...572 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 24 SAVE Commands...
Page 900: ...900 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 28 TIMebase Commands...
Page 1080: ...1080 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 31 WGEN w Commands...
Page 1142: ...1142 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 34 Error Messages...
Page 1344: ...1344 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide Index...