:SBUS<n>:USBPd:TRIGger
Command Syntax
:SBUS<n>:USBPd:TRIGger <mode>
<mode> ::= {PSTart | EOP | SOP | SPRime | SDPRime | SPDebug | SDPDebug
| HRST | CRST | CRCerror | PERRor | HEADer}
The :SBUS<n>:USBPd:TRIGger command selects the USB PD trigger mode:
• PSTart —
Preamble Start
, triggers at the start of a preamble, which starts with 0.
• EOP —
EOP
, triggers at the end of packet.
• SOP —
SOP
, triggers on ordered set Sync-1, Sync-1, Sync-1, Sync-2.
• SPRime —
SOP'
, triggers on ordered set Sync-1, Sync-1, Sync-3, Sync-3.
• SDPRime —
SOP''
, triggers on ordered set Sync-1, Sync-3, Sync-1, Sync-3.
• SPDebug —
SOP' Debug
, triggers on ordered set Sync-1, RST-2, RST-2, Sync-3.
• SDPDebug —
SOP'' Debug
, triggers on ordered set Sync-1, RST-2, Sync-3,
Sync-2.
• HRST —
Hard Reset
, triggers on ordered set RST-1, RST-1, RST-1, RST-2.
• CRST —
Cable Reset
, triggers on ordered set RST-1, Sync-1, RST-1, Sync-3.
• CRCerror —
CRC Error
, triggers when an error is detected on a 32-bit CRC.
• PERRor —
Preamble Error
, triggers when an error is detected on a 64-bit
sequence of alternating 0 and 1.
• HEADer —
Header Content
, triggers on a user-defined 16-bit value.
In this mode, use the :SBUS<n>:USBPd:TRIGger:HEADer command to select
the header type.
Query Syntax
:SBUS<n>:USBPd:TRIGger?
The :SBUS<n>:USBPd:TRIGger? query returns the selected USB PD trigger mode.
Return Format
<mode><NL>
<mode> ::= {PST | EOP | SOP | SPR | SDPR | SPD | SDPD | HRST | CRST
| CRC | PERR | HEAD}
See Also
•
•
":SBUS<n>:USBPd:TRIGger:HEADer"
•
":SBUS<n>:USBPd:TRIGger:HEADer:CMESsage"
•
":SBUS<n>:USBPd:TRIGger:HEADer:DMESsage"
•
":SBUS<n>:USBPd:TRIGger:HEADer:EMESsage"
•
":SBUS<n>:USBPd:TRIGger:HEADer:VALue"
•
Summary of Contents for P9241
Page 1: ...Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 6: ...6 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 36: ...36 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 1 What s New...
Page 41: ...Setting Up 2 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 41...
Page 44: ...44 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 2 Setting Up...
Page 222: ...222 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 7 Root Commands...
Page 244: ...244 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands...
Page 256: ...256 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands...
Page 278: ...278 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 10 CHANnel n Commands...
Page 328: ...328 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands...
Page 386: ...386 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands...
Page 390: ...390 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands...
Page 416: ...416 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands...
Page 498: ...498 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 21 MEASure Commands...
Page 532: ...532 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 22 MTESt Commands...
Page 572: ...572 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 24 SAVE Commands...
Page 900: ...900 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 28 TIMebase Commands...
Page 1080: ...1080 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 31 WGEN w Commands...
Page 1142: ...1142 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 34 Error Messages...
Page 1344: ...1344 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide Index...