22 EMERGENCY MODE
FUNC (K)/Ver. 1.01
Confidential
115
22.1.1 Emergency CH/GID Type
Configure the CH/GID Type for Emergency Mode.
Emergency CH/GID Type can be configured by using
KPG-101D. Emergency CH/GID Type can be used in the
following way.
Table 22-1 Emergency CH/GID Type Operation
Configuration using KPG-101D
•
Configuring the Emergency CH/GID Type (Refer
to FUNC 6.14.1 Emergency CH/GID Type.)
22.1.2 Emergency Zone-CH/GID
Emergency Zone-CH/GID can be used to configure the
Zone-CH/GID available in Emergency Mode if “Fixed” is
selected from the
Emergency CH/GID Type
dropdown
list.
The transceiver jumps to the Emergency Zone-
CH/GID in the following ways:
•
Pressing the
Emergency
key.
•
The switch that is connected to the Man-down tilt
switch input port is active.
Note:
The transceiver does not decode the Stun Code and
Optional Signaling in Emergency Mode.
Configuration using KPG-101D
•
Configuring the Emergency Zone-CH/GID (Refer
to FPRG 6.14.2 Emergency Zone-CH/GID.)
22.1.3 Emergency Cycle
Emergency Cycle is the number of times to switch
between transmission and reception in Emergency Mode.
Emergency Cycle can be configured by using
KPG-101D. Emergency Cycle activates in the following
way.
Table 22-2 Emergency Cycle Operation
Configuration using KPG-101D
•
Configuring the Emergency Cycle (Refer to FPRG
6.14.3 Emergency Cycle.)
22.1.4 Duration of Locator Tone 1
Duration of Locator Tone 1 is the alert tone beeping
before automatic transmission begins in Emergency
Mode.
This tone sounds when the transceiver alternates
between transmit and receive in Emergency Mode.
A user can easily recognize that the transceiver is about
to transmit the Emergency when the Tone sounds. The
dispatcher can use this tone to locate a user who is in an
emergency situation.
The Duration of Locator Tone 1 can be configured by
using KPG-101D.
Configuration using KPG-101D
•
Configuring the Duration of Locator Tone 1 (Refer
to FPRG 6.14.4 Duration of Locator Tone 1.)
Emergency
CH/GID Type
Operation
Selected
The transceiver transmits or
receives using the selected
CH/GID when the transceiver enters
Emergency Mode.
Fixed
The transceiver jumps to the Zone-
CH/GID configured in Emergency
Zone-CH/GID and begins
transmitting or receiving when the
transceiver enters Emergency
Mode.
Emergency Cycle
Operation
1 to 200
The transceiver repeats automatic
transmission start tone
automatic
transmission
automatic
transmission end tone
automatic
reception for configured number of
times and exits from Emergency
Mode.
Infinite
The transceiver alternates between
transmit and receive until the
Emergency
key is pressed or the
transceiver is turned OFF.