9 TIME-OUT TIMER (TOT)
32
Confidential
FUNC (K)/Ver. 1.01
9.2 Trunking System
(TK-3173 only)
The following timers relevant to Time-out Timer functions
can be configured in a Trunking System:
•
Time-out Timer (Dispatch)
•
Time-out Timer (Telephone)
9.2.1 Time-out Timer (Dispatch)
The Time-out Timer (Dispatch) is the maximum
continuous transmission time to communicate using the
Dispatch ID.
The transceiver pauses transmitting and emits the
Warning Tone when the transceiver attempts to transmit
after the configured Time-out Timer (Dispatch) expires.
The Warning Tone keeps sounding until the
PTT
switch is
released.
The maximum continuous transmission time using a
Dispatch ID can be configured by using KPG-101D.
Note:
The transceiver returns to receive mode after the EOT emits if
the timer pauses the transmission in FleetSync, etc.
The Time-out Timer (Dispatch) does not activate in Emergency
Mode.
Configuration using KPG-101D
•
Configuring the Time-out Timer (Dispatch) (Refer
to FPRG 6.3.8 Time-out Timer (Dispatch).)
9.2.2 Time-out Timer (Telephone)
The Time-out Timer (Telephone) is the maximum
continuous transmission time to communicate using the
Telephone ID.
The transceiver pauses transmitting and emits the
Warning Tone when the transceiver attempts to transmit
after the configured Time-out Timer (Telephone) expires.
The Warning Tone keeps sounding until the
PTT
switch is
released.
The maximum continuous transmission time using a
Telephone ID can be configured by using KPG-101D.
Note:
The transceiver returns to receive mode after the EOT emits if
the timer pauses the transmission in FleetSync, etc.
The Time-out Timer (Telephone) does not activate in
Emergency Mode.
Configuration using KPG-101D
•
Configuring the Time-out Timer (Telephone)
(Refer to FPRG 6.3.9 Time-out Timer
(Telephone).)