3.5
Changing the Zone-channel
The Zone-channel can be changed using the
Selector
(Portable only) or
PF
keys.
Changing the Zone
The zone can be changed by operating the
Selector
(Portable only) or
PF
keys.
Portable
0
Changing the zone according to the number indicated by the pointer of the Selector
Rotating the
Selector
causes the transceiver to migrate to the zone having the same number specified by the
Selector
.
Zones that can be selected are limited to zone 1 to zone 16.
If an unprogrammed zone is selected, “**************” appears on the display.
This behavior can be realized by installing a stopper on the
Selector
, enabling
16 Zone/Channel Selector
, and assigning
the Zone Select function to the
Selector
. (Refer to
Available Functions for the Selector
0
Changing the zone regardless of the number indicated by the pointer of the Selector
Rotating the
Selector
clockwise increases the zone number in steps of 1. Rotating the
Selector
counterclockwise
decreases the zone number in steps of 1.
If an unprogrammed zone is selected, the zone will be skipped.
This behavior can be realized by disabling
16 Zone/Channel Selector
and assigning the Zone Up/ Down function to the
Selector
. (Refer to
Available Functions for the Selector
0
Changing the zone by using the PF key
Pressing the
Zone Up
key increases the zone number in steps of 1. Pressing the
Zone Down
key decreases the zone
number in steps of 1.
If “Zone Up (Continuous)” or “Zone Down (Continuous)” is assigned to the
Zone Up
or
Zone Down
key, the zone number
is increased or decreased continuously every 200 ms by pressing and holding the
Zone Up
or
Zone Down
key.
If an unprogrammed zone is selected, the zone will be skipped.
0
Changing the zone by using the Lever switch
Positioning the
Lever
switch to the [A] position migrates the transceiver to the zone configured in
Zone A (Lever A
Position)
.
Positioning the
Lever
switch to the [B] position migrates the transceiver to the zone configured in
Zone B (Lever B
Position)
.
Note
The operation for changing the zone changes depending on the configuration in
Rollover/ End Stop
. (Refer to
Mobile
Pressing the
Zone Up
key increases the zone number in steps of 1. Pressing the
Zone Down
key decreases the zone
number in steps of 1. KCH-20R (Featured Panel) is operated by using the Selector just as Portable.
If “Zone Up (Continuous)” or “Zone Down (Continuous)” is assigned to the
Zone Up
or
Zone Down
key, the zone number
is increased or decreased continuously every 200 ms by pressing and holding the
Zone Up
or
Zone Down
key.
If an unprogrammed zone is selected, the zone will be skipped.
Note
The operation for changing the zone changes depending on the configuration in
Rollover/ End Stop
. (Refer to
3 BASIC OPERATIONS
3.5 Changing the Zone-channel
Common FUNC (K, F)/Ver 2.20
40