Using the Vibrator
Vibrator
is the function to vibrate the transceiver when the transceiver receives an individual call with Optional Signaling,
an NXDN Status Message or a Short Message. With this function, a user can recognize that the transceiver is receiving a
call even in noisy environments or an environment requiring silence.
The vibrator functions under the following conditions:
Table 11-2 Conditions for the Vibrator to Function
System
Conditions
P25 Conventional
If a Selective Call matches
P25 Trunking
0
If the transceiver receives an Individual Call or Group Call
0
If the transceiver receives a Paging Call
0
If the transceiver receives a Telephone Call
NXDN Conventional
0
If the Optional Signaling matches
0
If the transceiver receives a Status Message (other than status 226)
0
If the transceiver receives a Short Message
0
If the transceiver receives a Paging Call
DMR Conventional
0
If the transceiver receives an Individual Call or Group Call (except an Unaddressed Call)
0
If the transceiver receives a Status Message (except an Emergency Termination Status)
0
If the transceiver receives a Short Message
0
If the transceiver receives a Paging Call
NXDN Trunking
0
If the transceiver receives an Individual Call or Group Call
0
If the transceiver receives a Status Message (other than status 226)
0
If the transceiver receives a Short Message
0
If the transceiver receives a Paging Call
Analog Conventional/
LTR Trunking
0
If the Optional Signaling matches
0
If the transceiver receives a Status Message (except the status number 88, 90, 91, and 92)
0
If the transceiver receives a Short Message
0
If the transceiver receives a Paging Call
The vibrator vibrates for 500 ms and stops for 500 ms, and repeats this cycle 10 times.
However, in the following cases, even if the conditions for the vibrator to function are satisfied, the vibrator does not function.
During this state, the “
” icon blinks.
0
When the transceiver receives another signal to match the Optional Signaling while the vibrator is activated after the
Optional Signaling matches
0
During the amount of time configured in
Auto Reset Timer
after pressing the
PTT
switch, if the transceiver is on a
channel where anything other than “None” is configured for Optional Signaling
0
When the transceiver receives the same call while the amount of time configured in
Auto Reset Timer
is counting
down
Pressing the
Vibrator
key toggles the Vibrator between enabled and disabled.
Vibrator can also be enabled or disabled by selecting “Vibrator” after entering Menu Mode by pressing the
Menu
key. (Refer
to
.)
11 EXTERNAL PORTS
11.1 Universal Connector
Common FUNC (K, F)/Ver 2.20
209