Configuring the Alert Tone (Alert Tone Pattern)
Alert Tone Pattern is the alert tone pattern when receiving a call with the optional signaling. An Alert Tone that is suitable
for a user’s environment can be selected.
Alert Tone Pattern can be used to select an Alert Tone from 8 patterns of Alert Tones. An Alert Tone pattern consists of 16
tones.
Alert Tone Pattern can be configured by using KPG-D1/ D1N. The following table shows the configuration items for the
Autodial List.
Table 6-11 Alert Tone Pattern
Alert Tone Pattern
Description
Frequency
The tone frequency can be configured. A frequency between 400 Hz and 2500 Hz can be
configured in steps of 10 Hz. Gap can be configured if “No Tone” is selected.
Length
The tone length can be configured. A tone length between 10 ms and 2500 ms can be configured
in steps of 10 ms. No tone sounds if 0 ms is configured.
Cycle
This function can be used to configure the number of times for the Alert Tone that sounds from
the transceiver. A number from 1 to 255 can be configured for the number of times. The Alert Tone
sounds from the transceiver until it is manually stopped if “Infinite” is configured. If it is intended
for the Alert Tone to sound multiple times, the Alert Tone does not sound from the transceiver
while the transceiver unmutes the speaker. Or, if the matching state of Optional Signaling is reset,
Alert Tone will also be disabled.
Interval
This function can be used to configure the timing to repeat the Alert Tone that sounds from the
transceiver. A time between 0 and 255 s can be configured in steps of 1 s.
Configuration using KPG-D1/ D1N
Configuring
Alert Tone Pattern
(
Transceiver Settings > Special Alert Tone)
6 SOUND
6.2 Tones that Sound When the Transceiver Receives a Call
Common FUNC (K, F)/Ver 2.20
117