16.11
Ignition Sense
In a Multi RF Deck/ Multi Control Head structure, turning the transceiver ON or OFF can be controlled by the ignition switch
of a vehicle. (Refer to
RF Decks and Control Heads are equipped with an Ignition terminal.
Behaviors of Each Ignition Terminal
0
Control Head Side
Connect a Control Head to the IGN terminal of a vehicle via KCT-72 (pin number: Pin 1) connected to the Control Head.
The ignition switch is enabled only on one of the Control Heads, therefore, the ignition switch can be easily connected
compared to if the ignition switch is connected to an RF Deck.
RF Deck 1
(Selected RF
Deck)
Ignition
RF Deck 2
(Unselected
RF Deck)
Control Head
1
KCT-72
Control Head
2
Figure 16-61 Example of When the Ignition of a Control Head Is Used
0
RF Deck Side
Ignition can be used by inputting IGN signals from a vehicle to the Ignition terminals of all of the connected RF Decks.
RF Deck 1
(Selected RF
Deck)
Ignition
RF Deck 2
(Unselected
RF Deck)
Control Head
1
Control Head
2
Figure 16-62 Example of When the Ignition of RF Decks Is Used
Note
For RF Deck Side, even if the Ignition status of only one of the RF Decks in a Multi RF Deck system is changed, the other
RF Decks cannot detect the change.
16 MULTI RF DECK/ MULTI CONTROL HEAD
16.11 Ignition Sense
Common FUNC (K, F)/Ver 2.20
299