0
If Horn Alert is not configured for both the Horn Alert key and Menu Mode
Horn Alert is activated in the following conditions:
0
When the received Group ID matches if “None” is configured in Optional Signaling of the Group ID which the transceiver
waits for and Horn Alert is enabled
0
When the received Group ID and Optional Signaling match if “DTMF” or “FleetSync” is configured in Optional Signaling
of the Group ID which the transceiver waits for and Horn Alert is enabled However, “FleetSync” needs to be configured
in Optional Signaling for a Paging Call.
0
When the Fix ID for which Horn Alert is enabled matches the received Group ID
Regardless of the above conditions, the configuration of Optional Signaling, and all other configurations related to Horn
Alert, the Horn Alert port is activated according to the configuration in Horn Alert Logic Signal when the transceiver receives
Status No.89 of Fleet Sync.
P25 Trunking System
In a P25 Trunking system, one of the following conditions needs to be satisfied to activate Horn Alert:
0
If the transceiver receives an Individual Call while Horn Alert is enabled
0
If the transceiver receives a Paging Call while Horn Alert is enabled
NXDN Trunking System
In an NXDN Trunking system, one of the following conditions needs to be satisfied to activate Horn Alert:
0
If the transceiver receives an Individual Call or a Group Call while Horn Alert is enabled
0
If the transceiver receives a Paging Call while Horn Alert is enabled
0
If the transceiver receives Horn Alert Status regardless of the Horn Alert configuration
Configuration using KPG-D1/ D1N
Configuring
Horn Alert Status
(
Transceiver Settings > NXDN > NXDN Information > Status > Option)
12 FUNCTIONS LINKED TO A VEHICLE
12.2 Controlling Vehicle Operation According to the State of the Horn Alert Port (Horn Alert)
Common FUNC (K, F)/Ver 2.20
231