The STO control card uses a spring-loaded terminal strip. Use the following
instructions when wiring the control terminals.
Required Tools:
Screwdriver SD 0.4 x 2.5 (DIN 5264)
1
Strip the line about 7mm
2
Plug screwdriver into the middle square slot
3
Plug stranded wire into the round slot; be sure no
wire is seen from the outside
4
Remove screwdriver and check if the wire is fixed.
Make sure that the stranded wire and not the
insulation is clamped.
3.2.1 Assembly of the
wires (F5-K)
D, E Housings
G, H, R, U, W Housings
X2A
X2B
X3B
X4A
X3A
X4A
X3B
X3A
X2B
X2A
Terminal Description
X2A
Control terminal strip
X2B
STO terminal block
X3A
Encoder Interface channel 1
X3B
Encoder Interface channel 2
X4A
HSP5 interface
Control Connections (Safety)