237
FB - Field Bus Parameters
Control Word (16-bit)
The control word consists of serial inputs.
The raw inputs may be masked with parameter FB05 Control Word Mask.
Bit:
Function:
0
Enable
1
Reset
2
Up
3
Down
4
Binary Speed Input 1
or Binary Position 1
5
Binary Speed Input 2
or Binary Position 2
6
Binary Speed Input 3
or Binary Position 3
7
Reserved
or Binary Position 4
8
Reserved
or Binary Position 5
9
Special Function 1
10
Special Function 2
11
Special Function 3
12
Special Function 4
13
Special Function 5
14
Special Function 6
15
Special Function 7
Bits 0 - 3
Basic control word bits consisting of Enable, Up, Down, and Reset.
Bits 4 - 8
Assignment of serial selected binary-coded inputs for either speed or position.
Bits 9 - 15
Serial input selection of special functions. Serial and discrete digital inputs
are independent unless assigned the same function; therefore, it is possible
to have up to 1
4 functions defined between both serial and digital inputs.
Serial and/or digital inputs assigned the same function will be OR activated.
The available functions are the same as those for discrete digital inputs,
described further under LI04.
Summary of Contents for COMBIVERT F5
Page 1: ...COMBIVERT F5 ELEVATOR DRIVE Reference Manual Version 3 34 0F5LUB K334...
Page 203: ...203 LP Positioning Parameters LS02 LS01 LP03 LS02 LS01 LP03...
Page 347: ...Notes...
Page 348: ......