123
LI - Input Parameters
LI03 = D(Level - High - Inspect. - Interm.) [Leveling at start], NUM = 4
US04
Digital Speed
Selection
Param.
Control Inputs
I1
I2
I3
I4
S
Z
ERO
-
0
0
0
0
S
L
EVELING
LS01
1
0
x
x
S
H
IGH
S
PEED
*
LS02
1
1
x
x
S
H
IGH
S
PEED
LS02
0
1
x
x
S
I
NSPECTION
LS03
0
0
1
x
S
I
NTERMEDIATE
1
LS05
0
0
0
1
* Valid only at start (once leveling speed is reached it is not possible
to accelerate up to high speed again until after zero speed has been
selected)
LI03 = D(Inspect. - Level - High - Interm.), NUM = 8
US04
Digital Speed
Selection
Param.
Control Inputs
I1
I2
I3
I4
S
Z
ERO
-
0
0
0
0
S
L
EVELING
LS01
0
1
x
x
S
H
IGH
S
PEED
LS02
0
0
1
x
S
I
NSPECTION
LS03
1
x
x
x
S
I
NTERMEDIATE
1
LS05
0
0
0
1
LI03 = D(Level - Int.2 - High - Inspect), NUM = 12
US04
Digital Speed
Selection
Param.
Control Inputs
I1
I2
I3
I4
S
Z
ERO
-
0
0
0
0
S
L
EVELING
LS01
1
0
x
x
S
H
IGH
S
PEED
LS02
0
0
1
x
S
I
NSPECTION
LS03
0
0
0
1
S
I
NTERMEDIATE
1
LS05
1
1
0
x
S
I
NTERMEDIATE
2
LS06
0
1
x
x
Symbol:
1
=
Input is active
0
=
Input is not active
x
=
Setting has no effect or doesn’t care
Summary of Contents for COMBIVERT F5