310
Parameter Reference
I = Induction Geared, IX = Induction Gearless, P = PM Geared, PX = PM Gearless
Para.
Name
Hex
v1.72
Motor/Gear Type
Setting
Options
NUM
Range
Units
Default
Pass
Level
I
IX
P
PX
Min.
Max.
Imp.
Met.
LI04
Input 1 Function (I1)
0384
-
No Function*
UPS Operation*
Reduced Torque*
Emergency Pr
ofile*
Emergency Generator Speed*
Fault Reset
External Fault
Brake Release Confirm.
Main Contactor Check
Earthquake Speed
Emergency Slowdown (ESD)
Position Selection
Position Deviation Reset
Teach Value
Up Direction
Down Direction
Speed Selection
ETS (Emergency Terminal
Slowdown)
NTS1 (Normal Terminal Slowdown
NTS2
NTS3
Inspection Speed
Regen Fault
Braking Transistor On
125% NTS
*Can be selected together
0
1
2
4
8
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
-
-
-
-
No Function
OEM
LI05
Input 2 Function (I2)
0385
-
Same as LI04
“
-
-
-
-
No Function
OEM
LI06
Input 3 Function (I3)
0386
-
Same as LI04
“
-
-
-
-
No Function
OEM
LI07
Input 4 Function (I4)
0387
-
Same as LI04
“
-
-
-
-
No Function
OEM
LI08
Input 5 Function (I5)
0388
-
Same as LI04
“
-
-
-
-
No Function
OEM
LI09
Input 6 Function (I6)
0389
-
Same as LI04
“
-
-
-
-
No Function
OEM
LI11
Input 8 Function (I8)
038B
-
Same as LI04
“
-
-
-
-
No Function
OEM
LI15
Direction Selection Inputs
038F
-
Direction Selection
Up and Down Inputs
Down Input Only
Up & Down AND Serial Control
Word
0
1
2
-
-
-
-
(0); Up and
Down Inputs
+ Function
by Direction
Inputs
OEM
Brake Function
Function by Direction Inputs
Function by Speed Selection
0
4
LI16
Custom Input Decoding
0390
-
-
-
00000000h
00000000h
OEM
LI20
Brake Switch Function
0394
-
General Reset
3 Auto Resets
Forced Reset
0
1
2
-
-
-
-
General
Reset
OEM
LI50
UPS Mode
03B2
-
Default
Easy Direction
0
1
-
-
-
-
Default
OEM
LI60
Correction is Inspection
03BC
Off
On
0
1
-
-
-
-
Off
OEM
LM01
Motor Power
0681
LF10
-
-
-
0.5
299.5
HP
-
10
Basic
0.3
225
-
kW
7.5
RO
RO
0.5
299.5
HP
-
Calculated
0.3
225
-
kW
Calculated
LM02
Motor Speed
0682
LF11
-
-
20
4000
rpm
-
1164
Basic
400
4000
-
rpm
1450
20.0
500.0
rpm
100.0
400
4000
1000
20.0
500.0
100.0
LM03
Motor Current
0683
LF12
-
-
1.0
1000.0
Amps
1.0
Basic
LM04
Motor Frequency
0684
LF13
-
-
4.0
200.0
Hz
-
60.0
Basic
4.0
200.0
-
Hz
50.0
4.0
200.0
Hz
50.0
LM05
Motor Voltage
0685
LF14
-
-
10
32000
V
400
Basic
10
500
V
100
LM06
Motor Power Factor
0686
LF15
-
-
0.5
1.00
-
0.90
Basic
NA
NA
NA
NA
NA
Summary of Contents for COMBIVERT F5
Page 1: ...COMBIVERT F5 ELEVATOR DRIVE Reference Manual Version 3 34 0F5LUB K334...
Page 203: ...203 LP Positioning Parameters LS02 LS01 LP03 LS02 LS01 LP03...
Page 347: ...Notes...
Page 348: ......