215
CH - Configuration Handling
The C
onfiguration Handling parameter group has the same functions as US05
Load Configuration, which is only accessible with the OEM level password
or higher.
The drive can be reverted back to default settings. The default settings are
customizable and may vary from those from KEB. The default settings must
be created using US05= 8 (create OEM default). To completely default the
keypad to KEB default settings, go to CH01 and select PI password (2).
Setting:
Description:
NUM
Off
No action taken
0
Factory Reset
Will load defaults, as created by controller
OEM
1
PI Password
Revert to KEB keypad default settings
2
All current parameter settings can be saved to flash memory on the keypad
operator for future access. Or, current keypad operator settings can be
downloaded to the drive if a new or different keypad operator is installed.
Saving to the flash provides a ‘backup point’ during adjustment and allows a
user to revert back to known settings.
Setting:
Description:
NUM
Off
No action taken
0
Save to Flash
All current parameter settings are saved to keypad
operator flash memory
1
Save to Card
This function is not available
2
Write to Drive
Current keypad operator settings downloaded to
drive
3
Previously saved parameters can be restored from keypad operator flash
memory to revert to previous settings. Or, current drive settings can be
uploaded from the drive onto a new or different keypad operator.
Setting:
Description:
NUM
Off
No action taken
0
Restore from Flash
Previously saved parameter settings are
restored from internal keypad operator
flash
1
Load Parameter List*
Loads data from .dw5 stored to flash.
2
Restore from Drive
Current drive settings are uploaded from
drive to keypad operator
3
Load Motor Data*
Loads data from .dw5 stored to flash.
4
6.12 CH - Configuration Handling Parameters
CH01
Default Parameters
CH02
Save Parameters
CH03
Restore Parameters