261
TS - Terminal Slowdown Parameters
Overview
The terminal slowdown parameters
configure the settings for inputs assigned
as Normal Terminal Slowdown (NTS) inputs. (LI04-11).
The purpose of the NTS inputs is to provide an expedited and/or an alternate
slowdown means when the elevator speed approaching a terminal landing is
greater than a defined level. If this level is exceeded, the drive will perform
an NTS stop; otherwise, the drive will continue as normal.
Up to three NTS speed thresholds in each direction can be set with each input
corresponding to an NTS speed threshold or two inputs can be binary-coded
(TS01 NTSD Mode). This provides multiple checks during slowdown as the
contract speed increases.
Speed
LS02
TS02
Direction
Dropped
NTSD 1
Speed
NTSD 2
Speed
NTSD 3
Speed
6.17 TS - Terminal Slowdown Parameters