122
LI - Input Parameters
Digital Speed Selection
Utilizes four inputs to select up t
o five different speeds.
Older KEB elevator software and worldwide variants are available. Because of
this, several different truth tables for the Digital Speed Selection are available:
Version:
LI03 Setting:
NUM
US Lift
D(Level - Correct. - High - Inspect.)
0
KEB (DE)
D(Level - High - Inspect. - Interm.) [Level at Start]
4
SFKEB
D(Inspect. - Level - High - Interm.)
8
-
D(Level - Int.2 - High - Inspect.)
12
The following are the corresponding logic tables. Although inputs I1...I4 are
shown, the inputs actually used for speed selection are configurable and
can be defined in LI04-11. Refer to Section 3.1.1 or 3.2.2 for input terminal
assignments.
LI03 = D(Level - Correct. - High - Inspect), NUM = 0
US04
Digital Speed
Selection
Param.
Control Inputs
I1
I2
I3
I4
S
Z
ERO
-
0
0
0
0
S
L
EVELING
LS01
1
0
x
x
S
H
IGH
S
PEED
LS02
0
0
1
x
S
I
NSPECTION
LS03
0
0
0
1
S
C
ORRECTION
LS04
0
1
x
x
S
I
NTERMEDIATE
1
LS05
1
1
0
x
Symbol:
1
=
Input is active
0
=
Input is not active
x
=
Setting has no effect or doesn’t care