154
LM - Motor Data Parameters
This parameter is not applicable to Induction motors and therefore will not
appear.
Maximum motor inductance.
This value can be learned with a Motor Tune. Refer to Section 5.9 for
further details.
This parameter is not applicable to Induction motors and therefore will not
appear.
This parameter selects the relationship between the motor rated and maximum
inductances. It is determined by the drive and is used as part of the LL05 SPI
function. If the LM01 Motor Tune has been completed, this parameter should
not need adjustment and is only available for advanced troubleshooting.
Settings:
NUM
Ld <> Lq
0
Ld = Lq
1
Default = Ld <> Lq (0)
This value can be learned with a Motor Tune. Refer to Section 5.9 for
further details.
i
LM27
Motor Inductance
Mode
i
LM26
Motor Ls Max