177
LS - Speed Profile Parameters
Inspection Speed Pr
ofile Rate Settings
Acceleration rate for Inspection Speed profile.
Start Jerk rate into acceleration for Inspection Speed.
Acceleration Jerk rate into inspection speed for Inspection Profile.
Deceleration rate for Inspection Speed profile. If the enable is dropped when
the user releases the inspection switch, there will be no deceleration.
Jerk rate out of inspection speed for Inspection Speed profile.
Jerk rate out of deceleration into leveling speed and from leveling speed to
zero speed for Inspection Speed profile.
LS50
Acceleration Inspection
LS51
Start Jerk Inspection
LS52
Acceleration Jerk
Inspection
LS53
Deceleration
Inspection
LS54
Deceleration Jerk
Inspection
LS55
Stop Jerk Inspection