173
LS - Speed Profile Parameters
High Speed Profile Rate Settings
Acceleration rate for High Speed pr
ofile.
Start Jerk rate into acceleration for High Speed profile.
Acceleration Jerk rate into high speed for High Speed profile.
Deceleration rate for High Speed profile.
Jerk rate out of high speed into deceleration for High Speed profile.
Jerk rate out of deceleration into leveling speed.
The amount of leveling distance to be eliminated from a High Speed run.
This adjustment can provide additional time running at the run speed after
the slowdown speed has been given to reduce the amount of time at leveling
speed. A value of 0 will have no effect, whereas a value too large may lead to
overshooting the floors. When decelerating from High Speed, it is necessary
to transition directly from high speed to leveling. Selecting another speed in
between will cancel the function.
LS20
Acceleration High
Speed
LS21
Start Jerk High Speed
LS22
Acceleration Jerk High
Speed
LS23
Deceleration High
Speed
LS24
Deceleration Jerk High
Speed
LS25
Stop Jerk High Speed
LS27
High Speed Correction