124
LI - Input Parameters
Binary Speed Selection
Utilizes three binary-coded inputs for up to 7 speeds.
Older KEB elevator software and worldwide variants are available. Because of
this, several different truth tables for the Binary Speed selection are available:
Versions:
LI03 Setting:
NUM
US Lift
1.60, 1.62, 1.72 B(Level - Correction - Inspection)
0
US Lift
1.51, 1.61, 1.71 B(Inspection - Level - Correction)
1
Euro Lift
1.00, 2.20
B(Level - Correction - High)
2
-
-
LI16 Custom Input Decoding
3
The following are the corresponding logic tables. Although inputs I2...I4 are
shown, the inputs actually used for speed selection ar
e configurable and
can be defined in LI04-11. Refer to Section 3.1.1 or 3.2.2 for input terminal
assignments.
Custom binary table selections can be created with LI16 Custom Input
Decoding.
LI03 = B(Level - Correction - Inspection), NUM = 0
US04
Binary Speed
Selection
Parameter
Control Inputs
I2
I3
I4
S
Z
ERO
-
0
0
0
S
L
EVELING
LS01
1
0
0
S
H
IGH
LS02
0
0
1
S
I
NSPECTION
LS03
1
1
0
S
C
ORRECTION
LS04
0
1
0
S
I
NTERMEDIATE
1
LS05
1
0
1
S
I
NTERMEDIATE
2
LS06
0
1
1
S
I
NTERMEDIATE
3
LS07
1
1
1
Symbol:
1
=
Input is active
0
=
Input is not active
i