168
LS - Speed Profile Parameters
Zero Speed Offset. When this parameter is set to a speed other than zero and
only the enable and direction signals have been sent to the drive (no speed
command), the motor will be run at the offset speed programmed in LS00.
This function only applies to binary and digital speed control modes.
Max. Value: 2 fpm
Leveling speed. During Leveling Speed, a higher selected speed will be
ignored unless zero speed is commanded beforehand.
Max. Value: 25 fpm*
*
an upper limit of 59fpm can be achieved when LX50 Unlock LS01 is activated
High Speed. This speed setting uses the High Speed pr
ofile settings LS20-25
and LS27 Correction Distance.
The High Speed must also be set when US04 Control Type = Bi-Polar
Analog Speed (3), Absolute Analog Speed (2), Serial Speed DIN66019
Service 49 (4), Serial Speed DIN66019 Service 50 (5).
Max. Value: US06 Contract Speed
Inspection Speed. This speed setting uses the Inspection Speed profile
settings LS50-55. If the Inspection Speed command is present when the drive
is enabled, the inspection profile will be loaded. During the inspection speed
profile, all other speeds except Leveling Speed will be ignored.
Max. Value: 150 fpm
Correction Speed, also known as High Leveling Speed. During Correction
Speed, a higher selected speed will be ignored unless zero speed is
commanded beforehand. This speed setting uses the High Speed profile
settings LS20-25 and LS27 Correction Distance
Max. Value: 50 fpm
If the LI60 (Correction / Inspection) input is turned on, the drive will
allow the controller to switch between inspection and correction speed
commands (zero speed command not required). This only applies when
US04 Control Type = Binary Speed Control (1).
Intermediate Speed 1. This speed setting uses the One Floor Speed profile
settings LS30-35 and LS37 Correction Distance. Max. Value: US06 Contract
Speed
LS00
Zero Speed
LS01
Leveling Speed
LS02
High Speed
i
LS03
Inspection Speed
LS04
Correction Speed
i
LS05
Intermediate Speed 1
Summary of Contents for COMBIVERT F5
Page 1: ...COMBIVERT F5 ELEVATOR DRIVE Reference Manual Version 3 34 0F5LUB K334...
Page 203: ...203 LP Positioning Parameters LS02 LS01 LP03 LS02 LS01 LP03...
Page 347: ...Notes...