1) The wire gauge is based on the maximum fuse rating, copper wire with a 75°C insulation rating, THHW or equivalent. If circuit protection is selected
based on the actual input current, the wire size could be reduced.
2) This is the peak output current limited by hardware regulation. The software current control reserves 5% for closed loop regulation.
3) This is the maximum carrier frequency the power stage can support. The actual operating carrier frequency is adjusted and limited by the control
card.
4) This is the power dissipation at the rated carrier frequency, rated voltage, and rated load. Operation at reduced carrier frequencies or reduced load
will decrease this value.
5) Max motor cable length when using shielded cable, KEB EMI filter, and the installation must conform to EN55011 / EN55022.
Inverter Size
19
20
21
23
Max Motor Power
[hp]
40
50
60
100
Housing Size
R
R
R
U
Unit Hardware
B
B
B
B
D
Input Ratings
Supply voltage [V]
180...260 +/- 0 (240V Nominal Voltage)
Supply voltage frequency [Hz]
50 / 60 +/- 2
Input phases
3
3
3
3
Rated input current [A]
126
143
169
264
UL minimum wire gauge
1)
[awg]
2
2
6
2
UL maximum wire gauge
1
[awg]
4/0
4/0
1/0
300 kcmil
Output Ratings
Rated output power [kVA]
46
59
71
115
Rated motor power [kW]
30
37
45
75
Rated output current [A]
115
130
154
224
Peak current (30 seconds)
2)
[A]
230
217
270
363
450
Over current fault (E.OC) trip level [A]
276
270
315
435
540
Output voltage [V]
3 x 0...V input (3 x 0...255V
2)
)
Output frequency [Hz]
Generally 0 to 599Hz (limited by control board and carrier frequency)
Rated switching frequency [kHz]
8
8
8
4
Maximum switching frequency
3)
[kHz]
16
16
16
8
Power loss at rated operation
4)
[W]
1200
1400
1700
3000
Stall current at 4kHz [A]
123
160
198
319
396
Stall current at 8kHz [A]
115
145
180
203
252
Stall current at 16kHz [A]
70
101
101
–
Braking Circuit
Min. braking resistance [Ohm]
3.9
2.0
2.0
1.2
1.2
Typ. braking resistance [Ohm]
4.7
3.9
3.0
1.5
1.5
Max. braking current [A]
102
160
160
340
340
Installation Information
Max. shielded motor cable length
5)
[ft]
165
Tightening torque for power terminals [in lb]
53
220
Environmental
Max. heat sink temperature TOH [°C]
90°C / 194°F
Storage temperature [°C]
-25...70 °C / -13…158°F
Operating temperature [°C]
-10...45 °C / 14…113°F
Housing design / protection
Chassis / IP20 / Pollution Degree 2
Relative humidity
max. 95% without condensation
Approvals
Tested in accordance with…
EN 61800-3 /UL508C
Standards for emitted interference
EN 55011 Class B / EN 55022 Class A
Standards for noise immunity
IEC 1000-4-2 / -3 / -4 / -5/ -6
Climatic category
3K3 in accordance with EN 50178