92 of 112
Operating the Reader Using the ReaderStart Software
②
Info
shows the information about the tag manufacturer and the chip type
►
Click on the information symbol.
➯
The information about the tag is shown:
14.9.2 Password for Operation
1
Fig. 57: TestGen2: password for operation
①
Password
sets the password for the tag operation in the hexadecimal format
14.9.3 Write EPC
In this tab, it is possible to change the EPC of the tag.
2
3
4
1
Fig. 58: TestGen2: write EPC
①
New EPC
enters an EPC in the hexadecimal format
Make sure to comply with the maximum EPC length supported by the tag. If the max-
imum length is exceeded, the tag will return an error.
②
Auto increment
activates or deactivates increasing the EPC by one with each successful writing process
③
Write EPC to
selected tag
writes the EPC on the selected tag
④
Write EPC to tag
in field
writes the EPC entered in 1 to a single tag
►
When using this command, make sure ther
e is only one tag in the field. Otherwise, an err
or
message is displayed in the status field.