© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 1 9
Calibration and Testing
UBA Pro RT/RQ™ Series Banknote Recycler
Section 6
DIP Switch Test
To test the RT/RQ Unit DIP Switch’s performance,
proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches of the UBA Pro Unit as
below (Figure 6-80).
3. Set the DIP Switches of the RT/RQ Unit as below
4. Apply electrical power.
5. Confirm that the Status LED/Collect Button is lit
at
Green
Color and then turns off.
6. To start the Test, set the UBA Pro DIP Switch #8
to
OFF
7. Re-set the DIP Switches of the RT/RQ Unit as
below (Figure 6-84).
8. The UBA Pro
Green
Status LED will turn on
when the RT/RQ DIP Switches function properly.
9. Re-set the DIP Switches of the RT/RQ Unit as
below (Figure 6-86).
10. The UBA Pro
Red
Status LED will turn on when
the RT/RQ DIP Switches function properly.
11. Re-set the DIP Switches of the RT/RQ Unit as
below (Figure 6-88).
12. The UBA Pro
Green
and
Red
Status LEDs will
turn on when the RT/RQ DIP Switches function
properly.
13. Set the UBA Pro DIP Switch #8 to
ON
to end the
test.
Figure 6-80
Figure 6-80
DIP Switch Test 1
DIP Switches #1, #2, #5, #8 ON
ON
1
2
3
4
5
6
7
8
Figure 6-81
Figure 6-81
DIP Switch Test 2
DIP Switch #6 ON
ON
1
2
3
4
5
6
7
8
NOTE: Wait for the Status LED to turn off
in order to run the test properly.
Figure 6-82
Figure 6-82
DIP Switch Test 3
Green
ON
OFF
Figure 6-83
Figure 6-83
DIP Switch Test 4
DIP Switch #8 OFF
ON
1
2
3
4
5
6
7
8
Figure 6-84
Figure 6-84
DIP Switch Test 5
DIP Switches #1, #3, #5, #7 ON
ON
1
2
3
4
5
6
7
8
Figure 6-85
Figure 6-85
DIP Switch Test 6
Figure 6-86
DIP Switch Test 7
DIP Switches #2, #4, #6, #8 ON
ON
1
2
3
4
5
6
7
8
Figure 6-87
Figure 6-87
DIP Switch Test 8
Red
Figure 6-88
DIP Switch Test 9
DIP Switches All OFF
ON
1
2
3
4
5
6
7
8
Figure 6-89
Figure 6-89
DIP Switch Test 10
Red