Page 89
VIS CAM 300/400 Installation Manual
Appendix B: J-Panel Functional and Connector Description
6.12.5 Connecting Lane Controller RS485 signal between J-Panels
The Lane Controller RS485 signal is connected from one J-Panel to another by connecting RJ45 Patch
cables between X4 on the source J-Panel to X5 on the receive J-Panel. The RJ45 connectors have
build-in switch function to disconnect the termination resistor when the plug is inserted. When no plug
is inserted into the X4 connector the line is terminated with 120
Ω
.
The Lane Controller is connected to D0 on X15 J-Panel #1.
FIGURE 84.
Lane controller setup.