Goodrive100 inverters
Keypad operation procedure
IKR Aandrijven en Besturen
www.ikr-industries.nl
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P07.00
User’s
password
0~65535
The password protection will be valid when setting any non-
zero number.
00000: Clear the previous user’s password, and make the
password protection invalid.
After the user’s password becomes valid, if the password is
incorrect, users cannot enter the parameter menu. Only
correct password can make the user check or modify the
parameters. Please remember all users’ passwords.
Retreat editing state of the function codes and the password
protection will become valid in 1 minute. If the password is
available, press PRG/ESC to enter into the editing state of
the function codes, and then “0.0.0.0.0” will be displayed.
Unless input right password, the operator can not enter into
it.
Note: restoring to the default value can clear the password,
please use it with caution.
0
○
P07.02
QUICK/JOG
function
selection
0:No function
1:Jogging running. Press QUICK/JOG to realizes the jogging
running.
2:Shift the display state by the shifting key. Press
QUICK/JOG to shift the displayed function code from right to
left.
3:Shift between forward rotations and reverse rotations.
1
◎