Goodrive100 inverters
Product overview
IKR Aandrijven en Besturen
www.ikr-industries.nl
1. Autotune. If possible, de-coupled from the motor load to start dynamic autotune. Or if not, static
autotune is available.
2. Adjust the ACC/DEC time according to the actual running of the load.
3. Commission the device via jogging and check that the rotation direction is as required. If not, change
the rotation direction by changing the wiring of motor.
4. Set all control parameters and then operate.
2.2 Product specification
Function
Specification
Power input
Input voltage (V)
AC 3PH 400V±15%
Input current (A)
Refer to the rated value
Input frequency (Hz)
50Hz or 60Hz
Allowed range: 47~63Hz
Power
output
Output voltage (V)
0~input voltage
Output current (A)
Refer to the rated value
Output power (kW)
Refer to the rated value
Output frequency (Hz)
0~400Hz