Goodrive100 inverters
Installation guidelines
IKR Aandrijven en Besturen
www.ikr-industries.nl
Environment
Conditions
above 60
℃
.
In order to improve the reliability of the device, do not use the inverter if the
ambient temperature changes frequently.
Please provide cooling fan or air conditioner to control the internal ambient
temperature below the required one if the inverter is used in a close space
such as in the control cabinet.
When the temperature is too low, if the inverter needs to restart to run after a
long stop, it is necessary to provide an external heating device to increase
the internal temperature, otherwise damage to the devices may occur.
Humidity
RH
≤
90%
No condensation is allowed.
The maximum relative humility should be equal to or less than 60% in
corrosive air.
Storage
temperature
-40
℃
~
+
70
℃
, and the temperature changing rate is less than 1
℃
/minute.
Running environment
condition
The installation site of the inverter should:
keep away from the electromagnetic radiation source;
keep away from contaminative air, such as corrosive gas, oil mist and
flammable gas;
ensure foreign objects, such as metal power, dust, oil, water can not enter
into the inverter(do not install the inverter on the flammable materials such