Goodrive100 inverters
Keypad operation procedure
IKR Aandrijven en Besturen
www.ikr-industries.nl
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
effective
1:Only
∧
/
∨
keys adjustments is effective
2:Only digital potentiometer adjustments is effective
3:Neither
∧
/
∨
keys nor digital potentiometer adjustments are
effective
LED tens: frequency control selection
0:Only effective when P00.06=0 or P00.07=0
1:Effective for all frequency setting manner
2:Ineffective for multi-stage speed when multi-stage speed
has the priority
LED hundreds: action selection during stopping
0:Setting is valid
1:Valid during running, cleared after stopping
2:Valid during running, cleared after receiving the stop
command
LED thousands:
∧
/
∨
keys and digital potentiometer Integral
function
0:The Integral function is valid
1:The Integral function is invalid