Goodrive20-UL Series VFD
Optional peripheral accessories
-150-
Field
identifier
Field description
C
Voltage class
S2: AC 1PH 220V
–240V
04: AC 3PH 380V
–480V
D
3-digit code indicating the rated current. For example, 016 indicates 16A.
E
Filter performance
L: General
H: High-performance
F
Filter application environment
A: Environment Category I (IEC61800-3) category C1 (EN 61800-3)
B: Environment Category I (IEC61800-3) category C2 (EN 61800-3)
C.6.5 C2 filter model selection
Model
Input filter
Output filter
GD20-0R4G-S12
FLT-PS2010H-B
FLT-L04006L-B
GD20-0R7G-S12
FLT-PS2025L-B
FLT-L04016L-B
GD20-1R1G-S12
FLT-PS2025L-B
FLT-L04016L-B
GD20-0R4G-S2-UL
FLT-PS2010H-B
FLT-L04006L-B
GD20-0R7G-S2-UL
GD20-1R5G-S2-UL
FLT-PS2025L-B
FLT-L04016L-B
GD20-2R2G-S2-UL
GD20-0R4G-2-UL
FLT-P04006L-B
FLT-L04006L-B
GD20-0R7G-2-UL
GD20-0R7G-4-UL
GD20-1R5G-4-UL
GD20-2R2G-4-UL
FLT-P04016L-B
FLT-L04016L-B
Note:
The input EMI meets the C2 requirements after an input filter is configured.
The preceding table describes external accessories. You need to specify the ones you
choose when purchasing accessories.
C.7 Braking resistors
C.7.1 Braking resistor selection
It is appropriate to use braking resistor or braking unit when the motor brakes sharply or the
motor is driven by a high inertia load. The motor will become a generator if its actual rotating
speed is higher than the corresponding speed of the reference frequency. As a result, the
Summary of Contents for GD20-0R4G-2-UL
Page 1: ......