Goodrive20-UL Series VFD
Function parameters
-46-
Function
code
Name
Description
Default Modify
Note
: Setting mode 2
–7, 100% corresponds to
3 times of the motor rated current
P03.12
Keypad
setting
torque
Setting range: -300.0%
–300.0% (motor rated
current)
50.0%
○
P03.13
Torque
reference
filter time
0.000
–10.000s
0.100s
○
P03.14
Setting
source of
forward
rotation
upper-limit
frequency
in torque
control
0: Keypad setting upper-limit frequency
(P03.16 sets P03.14, P03.17 sets P03.15)
1: Analog AI1 setting upper-limit frequency
2: Analog AI2 setting upper-limit frequency
3: Analog AI3 setting upper-limit frequency
4: Pulse frequency HDI setting upper-limit
frequency
5: Multi-step setting upper-limit frequency
6: Modbus communication setting upper-limit
frequency
7
–9: Reserved
Note:
Setting method 1
–9, 100% corresponds
to the maximum frequency
0
○
P03.15
Setting
source of
reverse
rotation
upper-limit
frequency
in torque
control
0
○
P03.16
Torque
control
forward
rotation
upper-limit
frequency
keypad
defined
value
This function is used to set the upper limit of the
frequency. P03.16 sets the value of P03.14;
P03.17 sets the value of P03.15.
Setting range: 0.00 Hz
–P00.03 (Max. output
frequency)
60.00 Hz
○
P03.17
Torque
control
reverse
rotation
upper-limit
frequency
60.00 Hz
○