Goodrive20-UL Series VFD
Function parameters
-87-
Function
code
Name
Description
Default Modify
time of
stage 5
selected via code P00.06 or P00.07. When all
terminal 1= terminal 2= terminal 3= terminal 4
terminals aren't off, it runs at multi-step which
takes precedence of keypad, analog value,
high-speed
pulse,
PLC,
communication
frequency input. Select at most 16 stages
speed via the combination code of terminal 1,
terminal 2, terminal 3, and terminal 4.
The start-up and stopping of multi-step running
is determined by function code P00.06, the
relationship between terminal 1, terminal 2,
terminal 3, terminal 4 terminals and multi-step
speed is as following:
Terminal
1
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
Terminal
2
OF
F
OF
F
ON ON
OF
F
OF
F
ON ON
Terminal
3
OF
F
OF
F
OF
F
OF
F
ON ON ON ON
Terminal
4
OF
F
OF
F
OF
F
OF
F
OF
F
OF
F
OF
F
OF
F
step
0
1
2
3
4
5
6
7
Terminal
1
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
Terminal
2
OF
F
OF
F
ON ON
OF
F
OF
F
ON ON
Terminal
3
OF
F
OF
F
OF
F
OF
F
ON ON ON ON
Terminal
4
ON ON ON ON ON ON ON ON
step
8
9 10 11 12 13 14 15
Setting range of P10.(2n,1<n<17):
-100.0
–100.0%
Setting range of P10.(2n+1, 1<n<17):
0.0
–6553.5s (min)
P10.14
Multi-step
speed 6
0.0%
○
P10.15
The
running
time of
stage 6
0.0s
○
P10.16
Multi-step
speed 7
0.0%
○
P10.17
The
running
time of
stage 7
0.0s
○
P10.18
Multi-step
speed 8
0.0%
○
P10.19
The
running
time of
stage 8
0.0s
○
P10.20
Multi-step
speed 9
0.0%
○
P10.21
The
running
time of
stage 9
0.0s
○
P10.22
Multi-step
speed 10
0.0%
○
P10.23
The
running
time of
stage 10
0.0s
○
P10.24
Multi-step
speed 11
0.0%
○
P10.25
The
running
time of
stage 11
0.0s
○
Summary of Contents for GD20-0R4G-2-UL