Goodrive20-UL Series VFD
Function parameters
-86-
Function
code
Name
Description
Default Modify
P10.01
Simple
PLC
memory
selection
0: No memory after power-off
1: Memory after power-off; PLC memories its
running step and frequency before power-off.
0
○
P10.02
Multi-step
speed 0
100.0% of the frequency setting corresponds to
the Max. Frequency P00.03.
When selecting simple PLC running, set
P10.02
–P10.33 to define the running frequency
and direction of all stages.
Note:
The symbol of multi-step determines the
running direction of simple PLC. The negative
value means reverse rotation.
P10.02
P10.04
P10.06
P10.32
P10.30
P10.28
DEC time
(2 stages)
ACC time
(2 stags)
P10.03
P10.05
P10.07
P10.31
P10.33
Multi-step speeds are in the range of --f
max
–f
max,
and they can be set continuously.
Goodrive20-UL series VFDs can set 16 stages
speed, selected by the combination of
multi-step terminals 1
–4, corresponding to the
speed 0 to speed 15.
Output frequency
t
t
t
t
t
Terminal 1
Terminal 2
Terminal 3
Terminal 4
When terminal 1= terminal 2= terminal 3=
terminal 4=OFF, the frequency input manner is
0.0%
○
P10.03
The
running
time of
stage 0
0.0s
○
P10.04
Multi-step
speed 1
0.0%
○
P10.05
The
running
time of
stage 1
0.0s
○
P10.06
Multi-step
speed 2
0.0%
○
P10.07
The
running
time of
stage 2
0.0s
○
P10.08
Multi-step
speed 3
0.0%
○
P10.09
The
running
time of
stage 3
0.0s
○
P10.10
Multi-step
speed 4
0.0%
○
P10.11
The
running
time of
stage 4
0.0s
○
P10.12
Multi-step
speed 5
0.0%
○
P10.13
The
running
0.0s
○
Summary of Contents for GD20-0R4G-2-UL
Page 1: ......