Function parameters
-31-
Function
code
Name
Description
Default Modify
control when P00.06=7 or P00.07=7. It is
necessary to set P09. The running frequency of
the VFD is the value after PID effect. See P09
for the detailed information of the preset source,
preset value and feedback source of PID.
8: Modbus communication setting
The
frequency
is
set
by
Modbus
communication.
See
P14
for
detailed
information.
9
–11: Reserved
Note:
A frequency and B frequency can not set
as the same frequency reference method.
P00.08
B
frequency
command
reference
selection
0: Maximum output frequency, 100% of B
frequency
setting
corresponds
to
the
maximum output frequency
1: A frequency command, 100% of B frequency
setting corresponds to the maximum output
frequency. Select this setting if it needs to adjust
on the base of A frequency command.
0
○
P00.09
Combinati
on of the
setting
source
0: A, the current frequency setting is A
frequency command
1: B, the current frequency setting is B
frequency command
2: A+B, the current frequency setting is A
frequency c B frequency command
3: A-B, the current frequency setting is A
frequency command - B frequency command
4: Max (A, B): The bigger one between A
frequency command and B frequency is the set
frequency.
5: Min (A, B): The lower one between A
frequency command and B frequency is the set
frequency.
Note:
The combination manner can be shifted
by P05 (terminal function)
0
○
P00.10
Keypad
set
frequency
When A and B frequency commands are
selected as "keypad setting", this parameter will
be the initial value of VFD reference frequency.
60.00Hz
○