Goodrive20-UL Series VFD
Function parameters
-89-
Function
code
Name
Description
Default Modify
BIT13 BIT12 6
00
01
10
11
BIT15 BIT14 7
00
01
10
11
P10.35
BIT1
BIT0
8
00
01
10
11
BIT3
BIT2
9
00
01
10
11
BIT5
BIT4 10
00
01
10
11
BIT7
BIT6
11
00
01
10
11
BIT9
BIT8 12
00
01
10
11
BIT11 BIT10 13
00
01
10
11
BIT13 BIT12 14
00
01
10
11
BIT15 BIT14 15
00
01
10
11
After the users select the corresponding
ACC/DEC time, the combining 16 binary bit will
change into decimal bit, and then set the
corresponding function codes.
Setting range: -0x0000
–0xFFFF
P10.36
PLC
restart
mode
0: Restart from the first stage; stop during
running (cause by the stop command, fault or
power loss), run from the first stage after
restart.
1: Continue to run from the stop frequency;
stop during running (cause by stop command
and fault), the VFD will record the running time
automatically, enter into the stage after restart
and keep the remaining running at the setting
frequency.
0
◎
P10.37
Multi-step
time unit
selection
0: Seconds; the running time of all stages is
counted by second
1: Minutes; the running time of all stages is
counted by minute
0
◎