Goodrive20-UL Series VFD
Product overview
-8-
Function
Specification
Digital input
4 common inputs, max. frequency: 1kHz;
1 high speed input, max. frequency: 50kHz
Digital output
1 Y1 terminal output; 2 programmable relay outputs
Relay output
2 programmable relay outputs
RO1A NO, RO1B NC, RO1C common terminal
RO2A NO, RO2B NC, RO2C common terminal
Contact capacity: 3A/AC250V, 1A/DC30V
Others
Mountable method
Wall and rail mountable
Temperature of the
running
environment
-10
–50°C, derate above 40°C
Protective degree
Note:
1. The VFD with plastic casing should be installed in
metal distribution cabinet, which conforms to IP20
and of which the top conforms to IP3X.
2. Install device in pollution degree 2 environment
Cooling mode
Forced air cooling
Braking unit
Embedded
EMI filter
Optional filter: meet the degree requirement of IEC
61800-3 C2, IEC 61800-3 C3
Safety
Meet the requirements of CE, UL and CUL
Overvoltage
category
1PH&3PH 240V: Used in Canada only: "Transient
surge suppression shall be installed on the line side
of this equipment and shall be rated 240V (phase to
ground), 240V (phase to phase), suitable for
overvoltage category III, and shall provide protection
for a rated impulse withstand voltage peak of 4kV"
or equivalent.
3PH: Used in Canada only: "Transient surge
suppression shall be installed on the line side of this
equipment and shall be rated 480V (phase to
ground), 480V (phase to phase), suitable for
overvoltage category III, and shall provide protection
for a rated impulse withstand voltage peak of 6kV"
or equivalent.
Summary of Contents for GD20-0R4G-2-UL
Page 1: ......