Goodrive20-UL Series VFD
Function parameters
-62-
Function
code
Name
Description
Default Modify
voltage of the VFD)
7: Output power (relative to twice the rated
power of the motor)
8: Set torque value (relative to twice the rated
torque of the motor)
9: Output torque (relative to twice the rated
torque of the motor)
10: Analog AI1 input value
11: Analog AI2 input value
12: Analog AI3 input value
13: High speed pulse HDI input value
14: Modbus communication set value 1
15: Modbus communication set value 2
16
–21: Reserved
22: Torque current (corresponds to 3 times
rated current of the motor)
23: Ramp reference frequency (with sign)
24
–30: Reserved
P06.17
Lower
limit of
AO1
output
The above function codes define the relative
relationship between the output value and
analog output. When the output value exceeds
the range of set maximum or minimum output, it
will count according to the low-limit or
upper-limit output.
When the analog output is current output, 1mA
equals to 0.5V.
In different cases, the corresponding analog
output of 100% of the output value is different.
For detailed information, please refer to analog
output instructions in
Chapter 7
.
100.0%
0.0%
AO
10V (20mA)
Setting range of P06.17: -100.0%
– P06.19
Setting range of P06.18: 0.00V
–10.00V
0.0%
○
P06.18
Correspo
nding
AO1
output to
the lower
limit
0.00V
○
P06.19
Upper
limit of
AO1
output
100.0%
○
P06.20
The
correspon
ding AO1
output to
the upper
limit
10.00V
○