Figure 77: neoVI Explorer Network Enable/Disable Parameters.
Enable Networks on Boot
Normally, the neoVI FIRE 2 will not acknowledge messages on a network unless it is online
with that network or running a CoreMini script. When this option is enabled, the device always
acknowledges frames on all enabled networks.
Enable All
Enables all networks. Note that this may include enabling networks that are mutually exclusive
(such as SW CAN and LSFT CAN). If you use this option, be sure to disable networks that
should be off, so the device remains in a valid configuration.
Disable All
Disables all networks.
Performance Tests / USB Performance
Under
Performance Tests
is a single area called
USB Performance
. Here you will find a
test to check the performance of the FIRE 2’s USB connection (Figure 78). When
Enable
Performance Blast Test
is checked, the FIRE 2 sends high-speed traffic over the USB
connection to the PC.
Figure 78: neoVI Explorer USB Performance Test.