neoVI FIRE 2 User’s Guide
57
© 2016 Intrepid Control Systems, Inc.
Version 2.1 - October 10, 2016
ISO 15765-2
This page contains one setting:
IFS Shift Register
(Figure 75). Changing this from its default
value of 0 causes time to be added to the Inner Frame Spacing of USDT frames transmitted
by CoreMini scripts running in the FIRE 2. The number entered is multiplied by 6.4 µs to
determine the time offset. The allowed range is -1563 to 1563.
Figure 75: neoVI Explorer IFS Shift Register Parameter for ISO 15765-2.
Text API
These parameters control the operation of the text API that can be used to operate the neoVI
FIRE 2 using third party software. Please contact Intrepid if you require assistance with using
the API.
Figure 76: neoVI Explorer Text API Parameters.
Network Enables
This area provides more options for controlling the enabling and disabling of individual
networks within the FIRE 2 (Figure 77). The main display contains a scrollable list with
checkboxes that can be set or unset to enable or disable each network. These are equivalent
to the Enable checkboxes found in the parameter areas for the corresponding networks.