86
InnoMedia, Inc
.
All Right Reserved
System Information
These hidden commands can be invoked when troubleshooting and debugging a faulty SIP
Device unit.
Enabling Debug Mode (D1) & (D0)
Use the "
D1
" command to enable debug mode or the "D0" to disable it. After you have
enabled the debug mode, use the Tl command and enter a trace level. For most debugging
you will want D1 then Tl of 80.
SAMPLE:
D1
Debugging is enabled.
Tl
Please enter the level you want to trace:
80
Traces less than or equal to trace level 80 will be printed
out.
SIP Device Version Information (V)
Use command "
V
" to check SIP Device's current software version.
SAMPLE:
V
The Image Version is: 10.0.15
Control Code Version = 10.0.15 6308S Fri Aug 24 12:17:06 2007
DSP Code Version = 2.4.34 08/06 17:13 2007
BBS Version=7.3.18
SIP Stack Version=2.10.11
MCU Version=0.1.0
Hardware version = 10.5.0.0
Layout Version = A0-0
System Up Time:00 hours, 06 minutes, 51 seconds ago
Restoring System Default
The following procedures are used for restoring the default settings of an MTA.
Press <RSTR> button on the SIP Device for about 5 seconds. Then the message below will
show on HyperTerminal.