background image

User’s Manual

The SmartLiving System

9

2-2

The technologies

Expertise in the arena of total security and a commitment to precision and high
quality allow INIM's R & D professionals to deliver excellence in design technology
and dependability through time.

2-2-1

EASY4U

This user-friendly tool provides an interesting array of graphic features and
functions. All SmartLiving intrusion control panels are controlled by keypads
equipped with 96x32 pixel graphic displays. The four-line alphanumeric display
screen (16 characters per line) can be edited or used to view the icons associated
with various customized user-operations. The keypad shortcuts allow time-
consuming sequences to be transformed into simple keystroke actions. In this
way, frequently-used or repetitive sequences of keystrokes can be eliminated.
The shortcuts can be used for a variety of tasks and make operations less tedious
and less error-prone.  The use of customizable graphic-objects, which indicate
the system status, helps users to understand what is happening on the system..

Besides accepting various commands (Away Arm, Stay Arm, Disarm, etc.), the
nBy reader also allows users to manage the "shortcuts" programmed on the
keypad.

The JOY/MAX keypad provides a built-in nBy key reader.

2-2-2

VOIB

This is an acronym for 

V

oice 

O

ver 

I

nim-

B

us. VOIB technology allows the system

to manage end-to-end digitized voice transmissions at extremely high-speed over
the IBUS.  Voice transmissions can be carried to all points of the IBUS. The JOY/
MAX keypad provides a built-in microphone and speaker for message recording
and playback. The 30 minute capacity voice board allows each event to be
associated with a message. Voice digitizing and compression allow the signal to
be transmitted in data packets over the bus to recipient keypads where it is
announced.  Voice digitizing and the characteristics of the I-BUS allow end-to-end
“noise-immune” voice transmissions without the need of any additional wiring.

2-3

Keypads

The keypad allow users to manage all aspects of the security system.
SmartLiving control panels support JOY/GR, JOY/MAX, nCode/G and Concept/G
keypads. The features of these keypads are described in the following table:

The various keypad models provide diverse functions, casings and key access.
Joy keypads have a flip which protects the keys, whereas, the keys of the nCode/
G and Concept/G keypads are on view. The Concept/G is a touch keypad.

The keypad is the device that allows authorized code users to control the entire
system or specific partitions. However, system control can be extended to other
building occupants who do not hold a valid code.

The SmartLiving intrusion control panel offers an array of innovative features. In
addition to the traditional User menu (accessed by means of user-code entry),

Table 2: 

Keypads - functions

JOY/MAX

JOY/GR

nCode/G

Concept/G

Graphic display

Yes

Keys

23

(in soft rubber)

23

(touch)

Signaling LEDs

4

Buzzer

Yes

Terminals

2

1

Microphone

Yes

No

Loudspeaker

Yes

No

Built-in proximity reader

Yes

No

Temperature sensor

Yes

No

Backlight activated by proximity 

sensor

No

Yes

Block keypad

No

Yes

Summary of Contents for SmartLiving 10100L

Page 1: ...anual 1 S I S T E M I D I S I C U R E Z Z A GameOver MANUALE DI INSTALLAZIONE E PROGRAMMAZIONE USER S MANUAL S E C U R I T Y S Y S T E M S Certified by IMQ Security systems CEI 79 2 EN 50131 3 EN 5013...

Page 2: ...for damage arising from improper storage handling or use of this product Installation of this Product must be carried out by qualified persons appointed by INIM Electronics Installation of this Produ...

Page 3: ...he SmartLiving System 8 2 1 Introduction 8 2 2 The technologies 9 2 3 Keypads 9 2 4 Reader nBy 14 2 5 User Codes 15 2 6 Keys 16 2 7 Multi system access 17 2 8 Telephone functions 18 2 9 WEB e mail fun...

Page 4: ...ime request 33 5 13 Thermostat JOY MAX keypads only 34 5 14 Listen in 35 5 15 Partition status enquiry 35 5 16 Commands over the phone 35 5 17 Using the SmartLAN G 37 Appendix A Technical terminology...

Page 5: ...00 CEI EN 50131 3 2009 and CEI EN 50131 6 2008 Certification agency IMQ Security Systems Security rating 3 The following table describes the main features of the various models of the SmartLiving seri...

Page 6: ...charge optimization accessory item TamperNO tamper protection kit accessory item Backup battery 12 V 17 Ah Motherboard IN082 and IN088 integrated Type B notification apparatus The control panel compli...

Page 7: ...ce As the only individual in contact with system users it is the installer s responsibility to instruct them on how to use the security system properly Under normal circumstances the installer is not...

Page 8: ...ertake nBy readers 2 versions available nBy S wall mount and By X flush mount allow you to access and control the system Although these devices are not as flexible as keypads they provide a quick and...

Page 9: ...an be carried to all points of the IBUS The JOY MAX keypad provides a built in microphone and speaker for message recording and playback The 30 minute capacity voice board allows each event to be asso...

Page 10: ...mity sensor which can be activated by pressing keys and simultaneously and deactivated by pressing and The other option block unblock keypad can be achieved by pressing key for 3 seconds If the block...

Page 11: ...in the fact that in case B the red LED on the keypad blinks Case D is viewable only when the conditions of cases A B and C are not present Table 3 The icons shown on the second line of the display Ic...

Page 12: ...Codes each time it is pressed ESC Exits the User menu without changing the selected item parameter etc ENABLE Enables options refer to paragraph 5 4 Activations DISABLE Disables options F1 F2 F3 F4 or...

Page 13: ...occurs more than 5 times when the partitions are armed it will not be signaled as having occurred more than 5 times This is due to the limitation placed on the counter of each event The counters will...

Page 14: ...The buzzer signals the running Entry Exit and Pre arm time of the reader partitions refer to paragraph 2 3 6 Signaling on the Buzzer 2 4 1 Signaling on the Reader LEDs The LEDs have two distinct oper...

Page 15: ...ing commands will affect the code partitions only Timer Restriction If a code is associated with one of the timers it will be able to operate the system only when the Timer is On Group of outputs whic...

Page 16: ...ich are available in three versions nKey proximity keyfob nCard proximity card Air2 KF100 wireless keyfob Each key is unique and is identified by a random code selected from over 4 billion code combin...

Page 17: ...essful but the corresponding LED fails to light it is an indication that the battery is low The battery must be replaced before it runs out completely 2 7 Multi system access Users can access several...

Page 18: ...changes whatsoever should be made to the e mail structure Each e mail text is capable of containing a direct link to a website or to an IP addressable device such as an IP camera and an attachment do...

Page 19: ...tions The shortcut will affect all the keypad partitions 3 Code users only Press the respective key then enter a valid code the shortcut will activate after code recognition The shortcut will affect t...

Page 20: ...y a series of visual signals on the reader LEDs will indicate the various shortcuts When the required shortcut is indicated remove the key to activate the corresponding shortcut action The visual sign...

Page 21: ...the partitions are armed the LED sequence will start at point 6 3 3 3 Keyfob shortcuts To activate the shortcuts programmed by your installer assigned to the 4 keys on the keyfob simply push the butto...

Page 22: ...MAX keypad at address 1 Each JOY MAX keypad has a memo box for user memo recording playback This handy function will allow you to leave messages for other users who have access to the keypad refer to...

Page 23: ...ribed in paragraph 3 3 Key and Reader shortcuts Over the phone During a call from to the control panel after valid code PIN entry Via Command Zone After violation of a duly programmed zone which sends...

Page 24: ...command Internet as follows If you enter an arm partition s command at a keypad and not all the respective zones are in standby status thus execution of the command would generate an instant alarm th...

Page 25: ...it is possible to arm the partitions the zone belongs to disarm the partitions the zone belongs to switch the status of the partitions arm any disarmed partitions and disarm any armed partitions refer...

Page 26: ...sh to contact then press to send the call The recipient keypad will emit a series of beeps to signal an incoming call and the display will be as shown in the figure The recipient can press to answer t...

Page 27: ...g up the call the control panel will allow the installer company modem 30 seconds to establish communication If the modem fails to communicate within this period the control panel will play the pre re...

Page 28: ...r the value the better the signal If you access the control panel via browser it will be possible to view the status of Partitions menu Outputs Timer Events log Via Keypad Method 1 Activate the shortc...

Page 29: ...ccess to will be shown in the field in the lower part of the zone section after pressing the button if you are using a computer or after pressing if you are using a mobile telephone device Press the b...

Page 30: ...r the phone Type in the PIN of a user code followed by then press the key from 0 to 9 which the installer has programmed to trigger Activate outputs shortcut n 5 or Deactiv outputs shortcut n 6 Via Wi...

Page 31: ...re off if enabled the temperature value read by the built in temperature sensor will not be shown JOY MAX keypads only NoExitTimeSignal if enabled the buzzer will not emit audible signals during parti...

Page 32: ...PIN again using keys then press to save Method 2 Access the Change PIN section of the User Menu by means of a valid PIN Follow the instructions described in Method 1 5 10 Change telephone numbers Thi...

Page 33: ...uest postpones the auto arming operation by 30 minutes Via Keypad Method 1 Activate the shortcut assigned to the Overtime shortcut n 7 Method 2 Access the Overtime req section of the User Menu by mean...

Page 34: ...is a forced operation If the temperature drops below 2 C the output connected to the heating system will activate Via Keypad Method 1 Activate the shortcut assigned to the Thermostat shortcut n 37 and...

Page 35: ...PIN is assigned to Note If you activate this shortcut from a JOY MAX keypad the control panel will announce the armed disarmed status of the partitions the entered PIN is assigned to regardless of th...

Page 36: ...tores the control panel will send notification to the programmed users via SMS 5 16 4 SMS text message to the control panel If the system is equipped with a duly programmed Nexus dialer the user can o...

Page 37: ...lied by your installer and your user code PIN If you type the installer code this will be accepted only if the Teleservice is enabled paragraph 5 4 Activations 3 Press to start the connection Please n...

Page 38: ...wever they have two additional sections Table 10 Web server sections Icon Key Note Accessing the virtual keypad The keypad which is shown is the exact replica of the system keypad Use to select anothe...

Page 39: ...cipient can type in a valid PIN enabled for over the phone control and access the authorized functions ANSWERPHONE User operations on one or more partitions These generally indicate also the status of...

Page 40: ...ommon with the event element For example if a user arms several partitions from a keypad the events log will show description of the event Arm request description of the code and partitions involved d...

Page 41: ...l device activated deactivated by the control panel in response to programmed events OUTPUT A group of zones A partition identifies a group of zones that belong to a spatial or logical portion of the...

Page 42: ...aller company requires the user s collaboration and authorization before opening a teleservice session and working on the system via telephone line TELESERVICE A zone with this attribute cannot genera...

Page 43: ...ser Menu section Activations Timers 9 Voice menu Plays a recorded voice message which announces the shortcuts assigned to the number keys User code 27 Enab auto arm Accesses the User Menu section Acti...

Page 44: ...t operating properly Call your Installer company GSM fault SIM commun fault The SIM card does not respond or is not present The SIM card PIN is not disabled GSM fault Low credit The remaining credit o...

Page 45: ...User s Manual 45 Notes...

Page 46: ...46 User s Manual...

Page 47: ...User s Manual 47...

Page 48: ...er s Manual Azienda certificata ISO 9001 2008 via Fosso Antico Loc Centobuchi 63076 Monteprandone AP ITALY Tel 39 0735 705007 Fax 39 0735 704912 info inim biz www inim biz ISO 9001 2008 Registered com...

Reviews: