FAULT SIGNALS
The following table shows how system faults, indicated by the yellow LED, are
signaled clearly on the keypad
:
DCMUI
NE0S
LIVIN
GE
-R400-2
011012
1
FAULT
User menu string: “View/
Faults”
Probable cause
Note
Zone fuse blown
Zone fuse fault
Excessive current draw on the “+AUX” terminals
on the control panel
BUS fuse blown
IBUS fuse fault
Excessive current draw on the “+” terminal on
the control panel
Backup battery low or
disconnected
Low battery
The control panel backup-battery is running low
or is not connected properly
Primary power source
failure
Mains failure
The primary power source (230 Vac) has failed
(blackout) or is not connected properly
Telephone line down
Tel. line down
The telephone line is not working
Wireless noise
Jamming
Rogue wireless signal
Low wireless-detector
battery
Low battery WLS
The battery of at least one wireless detector is
running out
For information relating to
“Low battery WLS” and “WLS
zone loss” signaling, access
the User menu, “View/Faults”,
press
to view the list of
devices involved
Wireless detector loss
WLS zone loss
At least one wireless detector is not responding
(lost)
Fault on Nexus GSM
dialer
GSM fault / Low
signal
The GSM network signal is insufficient
Press
on “GSM fault” to
access the list of current faults.
GSM fault / GSM
module fault
The GSM module of the Nexus dialer is not
operating properly. Call your Installer company
GSM fault / SIM
commun.fault
The SIM card does not respond or is not present.
The SIM card PIN is not disabled.
GSM fault / Low
credit
The remaining credit on the SIM card is below
the minimum credit threshold.
GSM fault / Provider
missing
The GSM network provider of the SIM in use is
unavailable.
Loss or tamper running
LossTamp.ongoing
One of the following events is present:
•
Panel open
•
Panel dislodged
•
Expansion tamper
•
Keypad tamper
•
Reader tamper
•
Sound.flash.Tamp
•
Expansion loss
•
Keypad loss
•
Reader loss
•
Sound.flash.Loss
Faults on IVY-BUS
sounderflasher
Sounder faults / Horn
fault
A defect/damage has been detected on the horn/
sounder.
Press
on “Sounder faults” to
access the list of devices which
have at least one fault present.
Press
on the selected
sounderflasher to access the list
of current faults on the device
concerned.
Sounder faults /
LowBatt.Soundfl.
A low-voltage value has been detected on the
sounderflasher battery.
If the voltage drops below 10V, the device will
inhibit the sounder and activate only the flasher
(in the event of an alarm). If the voltage drops
below 8V, the device will inhibit both the sounder
and the flasher.
Sounder faults /
Battery resist.
An excessive internal resistance has been
detected on the sounderflasher battery. This type
of deep fault indicates corrosion inside the
battery, therefore, the battery must be replaced.
Violation of zones with
faults
Faults on zones
Violation has occurred on one or more zones with
the “Fault zone” option enabled.
Press
to access the list of
zones involved.