EonStor DS S48 Series Hardware Manual
3.7.3
Power On Status Check
As a general rule, once the system has been powered on, there should
NOT
be
LED(s) that light up
red
/
amber
nor should you hear an audible alarm from the
system. You should begin verifying system statuses via the following monitoring
interfaces:
LEDs on LCD keypad panel
:
The LED on the LCD keypad panel should
illuminate after a successful initialization process, indicating that system
status is ready. System initialization and the power-on self-test may take
up to five minutes and the system fault LED may light up during the
process. The system fault LED will turn off after a successful boot-up
process (refer to
LEDs on rear chassis, including controller module, PSUs, and cooling
modules (refer to
).
LCD Panel LEDs:
PWR LED: OFF
ATTN LED: OFF
Controller LEDs:
Status LED: On (green)
C_Dirty LED: Off
Temp LED: Off
CBM Status LED: On (green) or Off
PSU LEDs:
1
2
PSU
LED
(1)
: On (green)
Cooling fan LED
(2)
: Off (not lid)
74